Now that the gateway is set up, you are ready to configure the driver on the client. Since RSLinx sometimes runs as a service, I always reboot the computer if possible. At this point, under “Communications” choose to configure the gateway.īe sure to check “Enable RSLinx Gateway”, then choose “Apply” and “OK”.įinally, restart RSLinx.
#Rslinx classic copy configure drivers drivers#
Also, set up any drivers you need for your communication cards. The Title Bar of RSLinx should reflect this. On the Gateway Computer, be sure you have an RSLinx Gateway activation installed. You also improve your flexibility to access the Data Highway Plus network from potentially anywhere in the plant. Since the cost of a 1784-KTx module (or any other network module) is so high, you will save money in the long run.
#Rslinx classic copy configure drivers Pc#
Step 16) At this point if your PC is connected to the same subnet as your Micro800, you should see it appear in the RSWho window within 10 seconds. Step 15) Back in the RSLinx Classic RSWho window click on the “+” sign next to the “AB_ETH-1” driver (or double click on the “AB_ETH-1” driver) to expand the driver and start browsing: Step 14) Now select “Close” to close the “Configure Drivers” window: Step 12) Now enter in the Ethernet IP addresses of any Ethernet Micro800 PLCs you would like to connect to:
Step 11) The click on “OK” to accept the default driver name: Step 10) Open the RSLinx Classic “Configure Drivers” window again, and this time select the “Ethernet Devices” driver and click on “Add New”: If you can ping your Micro800 but the “Ethernet/IP Driver” does not find your Micro800 using auto-browse, continue on to the next step. Step 9) If your Micro800 does not appear, perform a Ping test as described in this article.
Step 8) At this point if your PC is connected to the same subnet as your Micro800, and there are no router or firewall settings preventing the Ethernet/IP Driver's auto-browse feature from working, you should see your Micro800 appear in the RSWho within 10 seconds. Step 7) Back in RSLinx Classic, in the RSWho window select the “+” sign next to the “AB_ETHIP-1” driver (or double click on the “AB_ETHIP-1” driver) to expand it and start browsing: Step 6) Now select “Close” to close the “Configure Drivers” window. Step 5) In the next window it's recommended to select the Ethernet device in your PC which is connected to your Micro800's network, and then select “OK”: Step 4) Now select “OK” to accept the default driver name: Step 3) In our first example we'll select the “Ethernet/IP Driver,” and then click on “Add New”:
Step 2) Under the “Available Driver Types” you'll see two different Ethernet Drivers: “Ethernet Devices” and “Ethernet/IP Driver” Step 1) Launch RSLinx Classic and then open “Configure Drivers” by selecting the Cable icon on the toolbar, or by choosing “Configure Drivers” in the “Communications” menu. Preface: Before proceeding it's a good idea to insure that the installed copy of RSLinx Classic is at least as new as your Micro800, as using old versions of RSLinx with new products does not always work.
#Rslinx classic copy configure drivers how to#
To program Rockwell's Micro820 and Micro850 over Ethernet you first need to know how to setup RSLinx Classic's Ethernet drivers, and in today's article I'll show you step-by-step how to do just that.